ORDINARY DUTY FLEX LSNH REELS
These cables are designed to be used in installations where smoke and acid gas emission would pose a major hazard in the event of a fire.
Ordinary duty flexible cords are used where the risk of mechanical damage and mechanical stresses is normal, i.e. when cables are subject to low mechanical stresses in the areas of application, and the risk of mechanical damage is low, as is the case to be expected in the normal use of small to medium size equipment in domestic and commercial as well as in light industrial premises. Examples of appliances that use ordinary duty flexible cords include vacuum cleaners, toasters, washing machines, refrigerators, dryers and televisions.
Quick Specifications
Group Code
318-B
Supplier
Doncaster Cables
Conductor
Plain Annealed Copper Class 5 Flexible to BS EN 60228
Insulation
Low Smoke Non Halogen
Sheath
Low Smoke Non Halogen
Min Operating Temperature
-15°C
Max Operating Temperature
70°C
Min Bending Radius
6 x diameter
Available Variations
| Name | Core Colours | Current Ratings | Unit | Weight | Colour | Bullet1 | Cable Types | Conductor Size | Details |
|---|---|---|---|---|---|---|---|---|---|
| 3182B 0.75 WHITE LSNH FLEX 100 MTR RLS | Blue and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 50.87 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 0.75 | View |
| 3182B 1.0 WHITE LSNH FLEX 100 MTR RLS | Blue and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 70.74 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 1 | View |
| 3182B 1.5 WHITE LSNH FLEX 100 MTR RLS | Blue and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 91.28 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 1.5 | View |
| 3183B 0.75 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 61.01 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 0.75 | View |
| 3183B 0.75 BLACK LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 61.01 | Black | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 0.75 | View |
| 3183B 1.0 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 71.8 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 1 | View |
| 3183B 1.5 WHITE LSNH FLEX 50 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 115.84 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 1.5 | View |
| 3183B 1.5 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 115.84 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 1.5 | View |
| 3183B 2.5 WHITE LSNH FLEX 50 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 151.13 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 2.5 | View |
| 3183B 2.5 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 151.13 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 2.5 | View |
| 3183B 4.0 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, and Brown | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 250.87 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 4 | View |
| 3184B 0.75 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, Brown, and Black | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 75.9 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 0.75 | View |
| 3184B 1.0 WHITE LSNH 100 MTR RLS | Green/Yellow, Blue, Brown, and Black | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 93.9 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 1 | View |
| 3184B 1.5 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, Brown, and Black | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 127.64 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 1.5 | View |
| 3184B 2.5 WHITE LSNH FLEX 100 MTR RLS | Green/Yellow, Blue, Brown, and Black | For current ratings refer to table 4F3A of BS7671 IET Wiring Regulations. | 1000 | 216.38 | White | Tested and quality assured by Doncaster Cables | LSNH INSULATED AND SHEATHED FLEXIBLE | 2.5 | View |